{"id":1444,"date":"2009-12-30T19:39:52","date_gmt":"2009-12-31T02:39:52","guid":{"rendered":"http:\/\/www.kbtechworks.com\/kbranch\/blog\/?p=1444"},"modified":"2009-12-30T19:52:03","modified_gmt":"2009-12-31T02:52:03","slug":"installing-a-xantrex-xw-%e2%80%93-part-2","status":"publish","type":"post","link":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/archives\/1444","title":{"rendered":"Installing a Xantrex XW \u2013 part 2"},"content":{"rendered":"<p>Today we mounted various components and started wiring things together. I&#8217;m afraid this will jump around a little. (And please if any one notices me doing anything suspicious, speak up.)  First thing today, I connected the thick cables that will bring power from the batteries to the inverter. There is one really large breaker\/disconnect between the batteries and where they connect to the inverter here. Note that I still have not connected the batteries to the system.<\/p>\n<div id=\"attachment_1448\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1448\" class=\"size-medium wp-image-1448\" title=\"xantrex-inverter-attach-battery\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-300x225.png\" alt=\"The heavy cables that bring power from the batteries\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery.png 2000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1448\" class=\"wp-caption-text\">The heavy cables that bring power from the batteries<\/p><\/div>\n<div id=\"attachment_1449\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-cover.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1449\" class=\"size-medium wp-image-1449\" title=\"xantrex-inverter-attach-battery-cover\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-cover-300x225.png\" alt=\"Xantrex provides covers for the power connectors\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-cover-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-cover-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-attach-battery-cover.png 2000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1449\" class=\"wp-caption-text\">Xantrex provides nice covers for the cables<\/p><\/div>\n<p>Next I mounted the other of the parts of the system: System Control Panel, Automatic Generator Start, and the Solar Charge Controller.  My continuing education made a jump today when I realized why there are two battery chargers in the system. The one in the inverter converts AC from the generator, (or the grid if you have such a thing) the Solar Charge Controller converts DC from the Solar Panel array for battery charging. (It&#8217;s smarter than that actually (see MPPT), but basically that is it.)<\/p>\n<div id=\"attachment_1458\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1458\" class=\"size-medium wp-image-1458\" title=\"xantrex-scp-ags\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-300x225.png\" alt=\"SCP and the AGS\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags.png 2000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1458\" class=\"wp-caption-text\">SCP and the AGS<\/p><\/div>\n<p>And, yes that is a giant heat sync built into the SCC.<\/p>\n<div id=\"attachment_1457\" style=\"width: 235px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scc.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1457\" class=\"size-medium wp-image-1457\" title=\"xantrex-scc\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scc-225x300.png\" alt=\"Solar Charge Controller (MPPT)\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scc-225x300.png 225w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scc-768x1023.png 768w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scc.png 1500w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><p id=\"caption-attachment-1457\" class=\"wp-caption-text\">Solar Charge Controller (MPPT)<\/p><\/div>\n<p>You will see what look like network cables running between the different component. And, indeed they are good old CAT5 network cables. All the devices talk to each other. There&#8217;s something a little funky in the system given that each device has two network connectors and the two ends have special terminators. It seems odd to me, but I assume they are doing interesting things. (One thing that I am sure of, is that they are providing power to some of the devices.)  Here&#8217;s a picture of everything mounted. The installation instructions tell you to run the network cables early because things get crowded later on. I took them at their word and ran the cables as soon as the everything was mounted.<\/p>\n<div id=\"attachment_1446\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-all-parts.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1446\" class=\"size-medium wp-image-1446\" title=\"xantrex-all-parts\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-all-parts-300x225.png\" alt=\"Xantrex XW system with accesories\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-all-parts-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-all-parts-1024x768.png 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1446\" class=\"wp-caption-text\">Xantrex XW system with accesories<\/p><\/div>\n<p>The next three pictures show the paths the network cabling take. Inside the PDP, there are special raceways for the network cabling. This is to shield the cables from interference and to help keep things organized.<\/p>\n<div id=\"attachment_1455\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1455\" class=\"size-medium wp-image-1455\" title=\"xantrex-inverter-network-cabling\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling-300x225.png\" alt=\"From the SCC to the inverter\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling.png 1000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1455\" class=\"wp-caption-text\">From the SCC to the inverter<\/p><\/div>\n<div id=\"attachment_1456\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling2.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1456\" class=\"size-medium wp-image-1456\" title=\"xantrex-inverter-network-cabling2\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling2-300x225.png\" alt=\"From the inverter to SCC and the AGS\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling2-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling2-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-network-cabling2.png 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1456\" class=\"wp-caption-text\">From the inverter to SCC and the AGS<\/p><\/div>\n<div id=\"attachment_1458\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1458\" class=\"size-medium wp-image-1458\" title=\"xantrex-scp-ags\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-300x225.png\" alt=\"SCP and the AGS\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-scp-ags.png 2000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1458\" class=\"wp-caption-text\">SCP and the AGS<\/p><\/div>\n<p>You don&#8217;t see cabling to the SCP because it&#8217;s in the wall. For some reason, the SCP mounting hardware really wants a hole in the wall for the network cable; I obliged.<\/p>\n<p>Now that I remember, the very first thing I did was install the air filter in the bottom of the inverter. You just push it in place with your hands.<\/p>\n<div id=\"attachment_1452\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-filter.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1452\" class=\"size-medium wp-image-1452\" title=\"xantrex-inverter-filter\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-filter-300x225.png\" alt=\"The air filter\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-filter-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-filter.png 1000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1452\" class=\"wp-caption-text\">The air filter<\/p><\/div>\n<div id=\"attachment_1451\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-bottom-closeup.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1451\" class=\"size-medium wp-image-1451\" title=\"xantrex-inverter-bottom-closeup\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-bottom-closeup-300x225.png\" alt=\"Close up of the inverter connections\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-bottom-closeup-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-bottom-closeup.png 755w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1451\" class=\"wp-caption-text\">Close up of the inverter connections<\/p><\/div>\n<p>The last thing for today was to connect up the wires that bring AC from the inverter to the breakers from which the house is the next stop.<\/p>\n<div id=\"attachment_1447\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ac-power.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1447\" class=\"size-medium wp-image-1447\" title=\"xantrex-inverter-ac-power\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ac-power-300x225.png\" alt=\"AC out from the inverter\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ac-power-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ac-power-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ac-power.png 2000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1447\" class=\"wp-caption-text\">AC out from the inverter<\/p><\/div>\n<p>And to ground the inverter.<\/p>\n<div id=\"attachment_1453\" style=\"width: 310px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ground.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1453\" class=\"size-medium wp-image-1453\" title=\"xantrex-inverter-ground\" src=\"http:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ground-300x225.png\" alt=\"The ground lug in the bottom of the inverter\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ground-300x225.png 300w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ground-1024x768.png 1024w, https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-content\/uploads\/2009\/12\/xantrex-inverter-ground.png 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1453\" class=\"wp-caption-text\">The ground lug in the bottom of the inverter<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Today we mounted various components and started wiring things together. I&#8217;m afraid this will jump around a little. (And please if any one notices me doing anything suspicious, speak up.) First thing today, I connected the thick cables that will bring power from the batteries to the inverter. There is one really large breaker\/disconnect between [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0,"footnotes":""},"categories":[4],"tags":[11,70],"class_list":["post-1444","post","type-post","status-publish","format-standard","hentry","category-brad","tag-solar","tag-xantrex"],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/posts\/1444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/comments?post=1444"}],"version-history":[{"count":0,"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/posts\/1444\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/media?parent=1444"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/categories?post=1444"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kbtechworks.com\/kbranch\/blog\/wp-json\/wp\/v2\/tags?post=1444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}